Stove size calculator

StoveRatings' planning range is heated square feet times a BTU-per-hour factor that depends on the band you pick.

For 2,000 square feet in the moderate band, 2,000 times 30 is 60,000 BTU/hr and 2,000 times 45 is 90,000 BTU/hr.

Those factors are ours, for an 8-foot ceiling, and they are not EPA figures or a room-by-room heat-loss calculation.

2,000 sq ft × 30 = 60,000 BTU/hr, and 2,000 sq ft × 45 = 90,000 BTU/hr. That is StoveRatings' planning range for this band, not an EPA figure.

The factors

StoveRatings planning factors, BTU per hour per square foot of heated floor
Band When we mean it Low factor High factor
Mild Winters usually stay above about 20°F 20 30
Moderate Winters often fall between 0°F and 20°F 30 45
Cold Winters often fall below 0°F 45 60
Severe Long stretches well below 0°F, or a drafty building 60 75

Formula: low BTU/hr = square feet × low factor. High BTU/hr = square feet × high factor. Compare a result with the heat-output range EPA listed for a model, which is a lab range, not the heat that will arrive in the room. The EPA snapshot date is 2026-10-23.

Use the finder to see those EPA heat-output ranges.