Mini Wood Stove: WS080, C080, D080, HO80, J080, N080, R080, T080, V080
Currently certified
EPA lists Mini Wood Stove: WS080, C080, D080, HO80, J080, N080, R080, T080, V080 under Enerco Group, Inc. as a currently certified non-catalytic wood stove.
The listed emission rate is 1.6 grams per hour.
The listed HHV efficiency is 72 percent.
Source: EPA Certified Wood Heater Database, snapshot 2026-10-23.
EPA rows
| Field | Row 1 |
|---|---|
| Status | Currently certified |
| Type | Wood Stove |
| Subtype | Non-Catalytic Stove |
| Emission | 1.6 grams per hour |
| HHV efficiency | 72 percent |
| Heat output | 10,710–26,631 BTU/hr |
| Firebox | 0.57 cu ft |
| CO | 0.74 g/min |
| Certified fuel | Crib Wood |
| Test method | Not listed |
| 2020 NSPS | Yes |
Retail names in the model line
These are the names split from EPA's model cell. They are aliases for this line, not separate listings.
- Mini Wood Stove
- WS080
- C080
- D080
- HO80
- J080
- N080
- R080
- T080
- V080
Other model lines from this manufacturer
- G2-A130WTS, G2-C130WTS, G2-H130WTS, G2-J130WTS, G2-N130WTS Currently certified
- G2-A50WTS, G2-C50WTS, G2-H50WTS, G2-J50WTS, G2-N50WTS Currently certified
- G2-A90WTS, G2-C90WTS, G2-H90WTS, G2-J90WTS, G2-N90WTS Currently certified
- G2-ABF66WTS, G2-CBF66WTS, G2-HBF66WTS, G2-JBF66WTS, G2-NBF66WTS Currently certified
- PS130W Model Line: C130W, N130WTS, H140XL, C140XL, J140XL, N140XL, J130W, N130W, H130W, C130WTS, H130WTS, J130WTS, and PS130WTS Currently certified
- PS20W Model Line: PS20W, PS20WTS, C30XL, H30XL, J30XL, N30XL, C20W, H20W, J20W, N20W, C20WTS, H20WTS, J20WTS, and N20WTS Currently certified
- PS60W Model Line: C60W, N60WTS, H80XL, C80XL, J80XL, N80XL, J60W, N60W, H60W, C60WTS, H60WTS, J60WTS, and PS60WTS Currently certified
- PSBF66W Model Line: CBF66W, NBF66WTS, H3W80XL, C3W80XL, J3W80XL, N3W80XL, JBF66W, NBF66W, HBF66W, CBF66WTS, HBF66WTS, JBF66WTS, and PSBF66WTS Currently certified
- WS090, C090, D090, H090, J090, N090, R090, T090, V090 Currently certified
- WS100, C100, D100, H100, J100, N100, R100, T100, V100 Currently certified
- WS110, C110, D110, H110, J110, N110, R110, T110, V110 Currently certified
- MINI 2 PCS Previously certified
- PS130W, PS130WTS, C140XL, H140XL, J140XL, N140XL, C130W, H130W, J130W, N130W, C130WTS, H130WTS, J130WTS, N130WTS Previously certified
- PS20W, PS20WTS, C30XL, H30XL, J30XL, N30XL, C20W, H20W, J20W, N20W, C20WTS, H20WTS, J20WTS, N20WTS Previously certified
- PS60W, PS60WTS, C80XL, H80XL, J80XL, N80XL, C60W, H60W, J60W, N60W, C60WTS, H60WTS, J60WTS, N60WTS Previously certified
- PSBF66W, PSBF66WTS, C3W80XL, H3W80XL, J3W80XL, N3W80XL, CBF66W, HBF66W, JBF66W, NBF66W, CBF66WTS, HBF66WTS, JBF66WTS, NBF66WTS Previously certified
Nearest model lines by EPA figures
Nearest means the smallest absolute difference on that EPA figure, among other Wood Stove model lines that list it. Ties are ordered by model name.
Emission
- 3.5 Series (Solution 3.5, Osburn 3500, Gateway 3500, Escape 2100, HT-3000, Solution 3.5-I, FW3500, Osburn 3500-I, HES350, Hei350, Blue Ridge 500, Escape 2100-I, CW3500, Blue Ridge 500-I) — 1.6 grams per hour
- 30-NC, 50-TNC30, 50-SNC30 — 1.6 grams per hour
- Ashley CAHF-2, Atlanta ACF-2, King MCF-2 — 1.6 grams per hour
- C.D. Lg. Fed. Convection Heater FA264CCL, FA264CCR — 1.6 grams per hour
- C.D. Lg. Fed. Convection Heater FA264CCL, FA264CCR — 1.6 grams per hour
HHV efficiency
- 15-W06, 50-SHW06, 50-SHW06L, 50TRW06, 15-W08, 50-SHW08, 50-SHW08L, 50TRW08 — 72 percent
- 2.3 Series (Archway 2300, FW2900, Gateway 2300, Green Mountain Insert 70, Escape 1800, Inspire 2000, Inspire 2000-I, Matrix, Escape 1800-I, Osburn 2000, Osburn 2000-I, Harmony 2.3, Solution 2.3, Solution 2.3-I, CW2900, Destination 2.3-I, Matrix-I, HES240, HEI240, Heritage, Deco Alto, Harmony 2.3-I, Blue Ridge 300P, Blue Ridge 300L, and Blue Ridge 300-I) — 72 percent
- 36 Elite — 72 percent
- 50TL — 72 percent
- Answer — 72 percent
Heat output
- Chinook Siroccco Ashford CK24C, CK24F, CK30C, CK30F, SC30, AF30 — 10,043–27,279 BTU/hr
- 24IC — 10,200–27,100 BTU/hr
- Vermont Castings Defiant 1975-CAT-C — 11,974–25,471 BTU/hr
- 3055 — 11,000–26,200 BTU/hr
- C.D. Federal "A Plus" FA224ACL — 7,200–30,000 BTU/hr